146
Built-in Outputs Section 6-2
Pulse Output Modes
There are two pulse output modes, independent mode is used when the num-
ber of pulses has been set and continuous mode is used when the number of
pulses has not been set.
INI(880)
MODE CONTROL
Stops the pulse output.
Changes the pulse output
PV. (This operation deter-
mines the origin location.)
Used Used Used Used Used ---
PRV(881)
HIGH-SPEED
COUNTER PV
READ
Reads the pulse output PV. Used Used Used Used Used ---
Instruction Function Positioning (independent mode) Speed control
(continuous mode)
Origin
search
Pulse
output
without
accelera-
tion/
decelera-
tion
Pulse output with
acceleration/deceler-
ation
Pulse
output
without
accelera-
tion/
decelera-
tion
Pulse
output
with
accelera-
tion/
decelera-
tion
Trapezoi-
dal, equal
accelera-
tion/
decelera-
tion rates
Trapezoi-
dal, sepa-
rate
accelera-
tion/
decelera-
tion rates
Mode Description
Independent mode This mode is used for positioning.
Operation stops automatically when the preset num-
ber of pulses has been output. It is also possible to
stop the pulse output early with INI(880).
Continuous mode This mode is used for speed control.
The pulse output will continue until it is stopped by
executing another instruction or switching the PLC to
PROGRAM mode.