61
PLC Setup Settings Section 4-2
Pulse Output 0 Search Compensation Value (Origin Compensation)
Note When the CX-Programmer is being used to make the setting, the setting is
input in decimal.
Pulse Output 0 Origin Search Acceleration Rate
Note When the CX-Programmer is being used to make the setting, the setting is
input in decimal.
Pulse Output 0 Origin Search Deceleration Rate
Note When the CX-Programmer is being used to make the setting, the setting is
input in decimal.
Pulse Output 0 Positioning Monitor Time
Note When the CX-Programmer is being used to make the setting, the setting is
input in decimal.
Programming
Console setting
address
Settings Default Function Related
Auxiliary
Area flags/
bits
Time when
setting is read
by CPU Unit
Word Bits
264 00 to 15 80000000 to
7FFFFFFF hex
(See note.)
---
Sets the pulse output 0 origin com-
pensation (−2,147,483,648 to
2,147,483,647).
--- When operation
starts
265 00 to 15
Programming
Console setting
address
Settings Default Function Related
Auxiliary
Area flags/
bits
Time when
setting is read
by CPU Unit
Word Bits
266 00 to 15 Pre-Ver. 2.0 CPU
Units: 0001 to
07D0 hex
CPU Units Ver.
2.0: 0001 to FFFF
hex
(See note.)
--- Sets the origin search acceleration
rate for pulse output 0.
Pre-Ver. 2.0 CPU Units:
1 to 2,000 pulses/4 ms
CPU Units Ver. 2.0:
1 to 65,535 pulses/4 ms
--- When operation
starts
Programming
Console setting
address
Settings Default Function Related
Auxiliary
Area flags/
bits
Time when
setting is read
by CPU Unit
Word Bits
267 00 to 15 Pre-Ver. 2.0 CPU
Units: 0001 to
07D0 hex
CPU Units Ver.
2.0: 0001 to FFFF
hex
(See note.)
--- Sets the origin search deceleration
rate for pulse output 0.
Pre-Ver. 2.0 CPU Units:
1 to 2,000 pulses/4 ms
CPU Units Ver. 2.0:
1 to 65,535 pulses/4 ms
--- When operation
starts
Programming
Console setting
address
Settings Default Function Related
Auxiliary
Area flags/
bits
Time when
setting is read
by CPU Unit
Word Bits
269 00 to 15 0000 to 270F hex
(See note.)
0000
hex
Specifies the positioning monitor time
(0 to 9,999 ms) for pulse output 0.
--- When operation