2-70
Note 2. The inputs at pins 40 to 46 and the outputs at pins 25 to 30 can be changed by parameter
settings. The settings in the diagram are the defaults.
Note 3. Pins 2, 4, 21, and 22 are for use with an absolute encoder.
Note 4. An automatic reset fuse is provided to protect output. If the fuse is activated for overcurrent, it
will automatically reset after a fixed period of time has lapsed without current flowing (sup-
ported by Servo Drivers with software version “r.0037” or later).
H Control I/O Signals
D CN1 Control Inputs
Pin
No.
Signal
name
Function Contents Control
mode
5 REF Speed command in-
put
Analog input terminal for speed commands. ±2 to ±10 V
(Servomotor forward rotation with + voltage)
Scale can be changed by means of user parameter
All
6 AGND Speed command in-
put ground
Scale can be changed by means of user parameter
Pn300 (speed command scale).
Can be used as a speed limit input for torque control (by
means of a Pn002.1 setting).
9 TREF Torque command in-
put
Analog input terminal for torque commands. ±1 to ±10 V
(Forward torque with + voltage)
Scale can be changed by means of user parameter
Pn400 (torque command scale)
All
10 AGND Torque command in-
put ground
P
n
400 (t
orque
comman
d
sca
l
e
)
.
Can be used as a torque limit input or torque feed for-
ward input for speed control or position control (by
means of a Pn002.0 setting).
3
PCOM Open collector com-
d l
To use open-collector output for inputting command
l d d i ti t t t th i t
All
13
p
mand power supply
pppg
pulses and deviation counter resets, connect the + inputs
to these terminals and connect the
inputs to open
-
col
-
18
to these terminals and connect the
inputs to open
-
col
-
lector output terminals.
7 +PULS/
CW/A
Feed pulses, reverse
pulses, or 90_ phase
difference pulses (A
Pulse string input terminals for position commands.
Line-driver input: 10 mA at 3 V
Position
8 –PULS/
CW/A
diff
erence
pu
l
ses
(A
phase)
Line driver input: 10 mA at 3 V
Maximum response frequency: 500 kpps
Open-collector input: 7 to 15 mA
Maximum response frequency: 200 kpps
11 +SIGN/
CCW/B
Direction signal, for-
ward pulses, or 90_
phase difference
Maximum response frequency: 200 kpps
Any of the following can be selected by means of a
Pn200 0 setting: feed pulses or direction signals (PULS/
12 –SIGN/
CCW/B
p
h
ase
diff
erence
pulses (B phase)
P
n
200
.
0
se
tti
ng:
f
ee
d
pu
l
ses
or
di
rec
ti
on
s
i
gna
l
s
(PULS/
SIGN); forward or reverse pulses (CW/CCW); 90_ phase
difference (A/B phase) signals (A/B).
14 –ECRST
Deviation counter re-
set
Line-driver input: 10 mA at 3 V
Open-collector input: 25 mA at 5 V
Position
15 +ECRST
Open collector input: 25 mA at 5 V
ON: Pulse commands prohibited and deviation counter
cleared.
4 SEN
Sensor ON input ON: Absolute encounter’s multi-turn amount and initial
incremental pulses sent.
All [absolute]
2 SENGND
incremental pulses sent
.
Required when using an absolute encoder.
21 BAT
Backup battery input Backup battery connector terminals for power interrup-
tion for absolute encoder
All [absolute]
22 BATGND
tion for absolute encoder
Connect the battery to either this terminal or CN8.
47 +24VIN +24-V power supply
input for control DC
Power supply input terminal (+24 V DC) for sequence
inputs (pins 40 to 46).
All
Standard Models and Specifications Chapter 2

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron OMNUC R88D-WT15HF and is the answer not in the manual?

Omron OMNUC R88D-WT15HF Specifications

General IconGeneral
BrandOmron
ModelOMNUC R88D-WT15HF
CategoryServo Drives
LanguageEnglish

Related product manuals