Raisecom Technology Co., Ltd
56
10.4.4. E1 using and mode information:
Indevice set query menu press number key 4, and there will be E1 using and mode
information:
E1: First Second Third Fourth
Real information:
Use: 1=Using 1 1 0 0
Mode: 1=PCM31 0 0 0 0
Mask: 1=Mask 0 0 0 0
EEPROM Set:
Use:1=Using 1 1 0 0
Mode:1=PCM31 0 0 0 0
Mask:1=Mask 0 0 0 0
Device Query Command: 1-8, Menu Display: M, Return: Q Command:
There are two parts information, one is the information saved in RAM and the other part
is the information saved in EEPROM.
10.4.5. Clock, CRC and Net information:
Indevice set query menu press number key 5, and there will be E1 using and mode
information:
Real information:
Clock Mode: Recovered Clock(1 E1) Auto
Net Topology: Single E1 Direction
Net Using Time Slot: 0 Time Slot
CRC Transmit: Enable
Alarm Sound Output: Disable
EEPROM information:
Clock Mode: Recovered Clock(1 E1) Auto
Net Topology: Single E1 Direction
Net Using Time Slot: 0 Time Slot
CRC Transmit: Enable
Alarm Sound Output: Disable
Device Query Command:1-8, Menu Display:M, Return:Q Command:
Note: clock modes: main clock
Recovered clock (1 E1)
Recovered clock (2 E1)
Recovered clock (3 E1)
Recovered clock (4 E1)
There are two ways to adapt clock: Auto
Manual