EasyManuals Logo
Home>Raisecom>Multiplexer>RC3000 PCM

Raisecom RC3000 PCM User Manual

Raisecom RC3000 PCM
86 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #60 background imageLoading...
Page #60 background image
Raisecom Technology Co., Ltd
59
Signal:Exist Signal In:Original Signal Out:Original
Signal Bit(D7:D0):A A A A A A A A
Device Query Command:1-8, Menu Display:M, Return:Q Command:
10.4.8. User-Board information (EEPROM)
Device Set Query menu press number key 8 you can get the same information saved in
EEPROM as User-Board information (RAM)
10.5. Cross Set Query menu:
In main menu press number key 2, there will be Cross Set Query menu:
1.Four E1 Cross Query(RAM)
2.Four User Cross Query(RAM)
3.Four E1 Cross Query(EEPROM)
4.Four User Cross Query(EEPROM)
CROSS Query Command:1-4, Menu Display:M, Return:Q Command:
Note: here you need to enter two commands (group number is required)
10.5.1. Four E1 Cross Query (RAM)
In Cross Set Query menu, press number key 1 and there will be the following
information:
Input Group No.(1-4, Esc=Cancel):1
Enter group number 1, cross connection of the first E1 will be displayed:
First E1 Cross Set
Channel 1 2 3 4 5 6 7 8
cross 0 0 0 | 5 2 | 5 3 | 5 4 | 5 5 | 5 6 | 5 7 | 5 8
8 0 0 | 0 0 | 0 0 | 0 0 | 0 0 | 0 0 | 0 0 | 0 0
16 5 17 | 5 18 | 5 19 | 5 20 | 0 0 | 0 0 | 0 0 | 0 0
24 0 0 | 0 0 | 0 0 | 0 0 | 0 0 | 0 0 | 0 0
CROSS Query Command:1-4, Menu Display:M, Return:Q Command:
Note: in this table the address indicates the output data direction and the contents
indicate the input data direction.
Data in each cell consists of two parts, the first part indicates cross group:
1: cross group 1 2: cross group 2 3: cross group 3 4: cross group 4
5: user E1 1 6: user E1 2 7: user E1 3 8: user E1 4
And the second part indicates the channel of cross group (the first part): 1-31, 0 0
indicates there is no cross connection.
Address indication: result of row number plus column number is the channel number. For
example: 5 17,the address is 16+1=17 that is to say the data in this cell is the cross
connection of the 17
th
channel of first E1 (cross group 1)