Mobile data storage units
5.8 MDS D200
MOBY D
System Manual, 01/2010, J31069-D0147-A6-7618
127
5.8.4 Technical data
Memory configuration
ï‚· Serial number
ï‚· Application memory
ï‚· 8 bytes (fixed code)
ï‚· 256 bytes
Storage technology EEPROM
Memory organization 4 bytes, block by block
Protocol according to ISO 15693
Data retention (at +25 °C) 10 years
MTBF (at +25 °C) 2 x 105 hours
ï‚· Read cycles
ï‚· Write cycles, min.
ï‚· Write cycles, typical
ï‚· Unlimited
ï‚· 100 000
ï‚· 1 000 000
Read/write distance (Sg) See Chapter Field data (Page 33)
Recommended distance to metal 25 mm (approx. 30% reduction of the field data)
Multitag capability Yes
Power supply Inductive power transmission (without battery)
Degree of protection according to EN 60529 IP67
Vibration ISO 10373/ISO 7810
Torsion and bending load ISO 10373/ISO 7816-1
Mechanical design
ï‚· Color
ï‚· Material
ï‚· Dimensions (L x W x H in mm)
Laminated plastic card, printable on both sides
ï‚· White
ï‚· PET
ï‚· 85 x 54 x 0.8
Mounting Adhesive, fixing lug
Ambient temperature
ï‚· Operation
ï‚· Transport and storage
 -20 °C to +60 °C
 -20 °C to +60 °C
Weight approx. 5 g

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC MOBY D and is the answer not in the manual?

Siemens SIMATIC MOBY D Specifications

General IconGeneral
BrandSiemens
ModelSIMATIC MOBY D
CategoryAccessories
LanguageEnglish

Related product manuals