Write/read devices with RS422 interface
7.5 SLG D12S (plug-in version)
MOBY D
194 System Manual, 01/2010, J31069-D0147-A6-7618
7.5 SLG D12S (plug-in version)
7.5.1 Features
SLG D12S (plug-in version) Features
Performance range The SLG D12S (plug-in version) is a
write/read device in the lower
performance range with serial interface.
Range up to 160 mm
Interface RS422 serial interface
8-pin M12 connector for
Power supply
Data communication
Communication via interface modules to SIMATIC S7 or
PROFIBUS DP-V1/PROFINET/Ethernet
IP
Connectable ASM
ASM 452
ASM 456
ASM 473
ASM 475
RF170C
RF180C
RF182C
Antenna integrated
Programming options e.g. via FB 45/FC 45
High degree of
protection
IP67
Multitag capability no

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC MOBY D and is the answer not in the manual?

Siemens SIMATIC MOBY D Specifications

General IconGeneral
Product designationSIMATIC MOBY D
Operating Frequency13.56 MHz
Operating Temperature-25°C to +70°C
DimensionsVaries by model
WeightVaries by model
Communication InterfaceRS232, RS422
Protection ClassIP67