MOBY D
System Manual, 01/2010, J31069-D0147-A6-7618
293
Troubleshooting/FAQ
12
What shall I do when nothing works?
1. Check the supply voltage directly on the SLG connector with a voltmeter.
2. Check the cables to the computer
Do the SLG and the computer have the same physical interface?
Is the polarity of the connecting cable (RS 232) correct?
(RxD of SLG must be connected to TxD of computer and vice-versa)
Is the cable shield connected correctly?
Error messages
More information on error messages can be found at MOBY D C/C++ MDWAPI
Programming Manual (http://support.automation.siemens.com/WW/view/en/12429971
).
The range of the SLG is too small
When the range of the SLG is too small, you must check
Power supply unit/switched-mode power supply (see the Section
Planning the MOBY D
system
regarding interference)
Whether monitors or other sources of interference are nearby (see the Section
Planning
the MOBY D system
)
Whether metal is in the immediate vicinity (see the Section
Planning the MOBY D
system
)
To achieve optimal write/read distances with ANT D5, a metal plate is required at a
distance of 100 mm (see the Section
Planning the MOBY D system
)

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC MOBY D and is the answer not in the manual?

Siemens SIMATIC MOBY D Specifications

General IconGeneral
BrandSiemens
ModelSIMATIC MOBY D
CategoryAccessories
LanguageEnglish

Related product manuals