System integration
9.1 ASM 452
MOBY D
238 System Manual, 01/2010, J31069-D0147-A6-7618
9.1.6 Cable
9.1.6.1 PROFIBUS DP cable with 24 V supply
The ASM 452 can also be operated with the "green" PROFIBUS DP cable. It is important to
ensure that a 24 V cable is connected from X12 to X13. The 24 V cable can be connected to
pins 5 and 6 in plug X12.
;
;
;
;
;
;
Figure 9-7 PROFIBUS DP cable with 24 V supply
9.1.6.2 Example of stripped lengths
The following diagram shows an example of stripped lengths. The lengths apply to all cables
which can be connected to the connector plugs. You must twist any shield braid present,
plug into a core end sleeve and cut off any excess.


7ZLVWHGDQG
WUXQFDWHG
VKLHOGEUDLGLQJ
Figure 9-8 Length of stripped insulation for PROFIBUS DP cables