C.2 Discontinued SLG with ANT D5
MOBY D
System Manual, 01/2010, J31069-D0147-A6-7618
319
C.2.3 SLG D11 ANT D5 (MLFB 6GT2601-0AC00)
Application area
SLG D11 ANT D5 is a write/read device in the mid performance range with a serial interface
and a separate antenna which has been specially designed for warehouses, logistics and
distribution. It is designed for a range of up to 380 mm (depending on the label).
The write/read device is equipped with a serial RS 232 interface which supports
communication with the PC or non-Siemens PLCs.
For fast and easy programming, a C library is available to the user that supports the use of
Windows 9x, 2000, NT and XP.
SLG D11 ANT D5 has multitag capability.
Figure C-13 Write/read device SLG D11 ANT D5
Ordering data
Table C- 10 Ordering data for SLG D11 ANT D5
Order no.
SLG D11 ANT D5 write/read device basic unit
with RS 232 serial interface for standard PC,
with separate antenna
6GT2601-0AC00
Accessories:
Spacer kit for ANT D5
Wide-range power supply unit for SIMATIC RF
systems (100 - 240 V AC / 24 V DC / 3 A) with 2 m
connecting cable and country-specific plug.
ï‚· EU
ï‚· UK
ï‚· US
Cables and connectors
6GT2690-0AB00
ï‚· 6GT2898-0AA00
ï‚· 6GT2898-0AA10
ï‚· 6GT2898-0AA20
see Chapter
Planning the MOBY D system

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC MOBY D and is the answer not in the manual?

Siemens SIMATIC MOBY D Specifications

General IconGeneral
BrandSiemens
ModelSIMATIC MOBY D
CategoryAccessories
LanguageEnglish

Related product manuals