Page #182 background imageLoading...
Page #182 background image
Write/read devices with RS422 interface
7.3 SLG D11S basic unit
MOBY D
182 System Manual, 01/2010, J31069-D0147-A6-7618
MTBF 2.0 x 10
5
hours
Degree of protection to EN 60529 IP65 (UL: For indoor use only)
Shock resistant to EN 60721-3-7,
Class 7M2
Total shock response spectrum,
Type II
30 g
Vibration resistance in accordance
with EN 60721-3-7, Class 7M2
1 g (9 to 200 Hz)/
1.5 g (200 to 500 Hz)
Weight, approx. 600 g
Approvals
ï‚· CE
ï‚· FCC
ï‚· IC
ï‚· Harmless to heart pacemakers
ï‚· UL 60950
7.3.4 FCC information
Siemens MOBY D SLG D11S
FCC ID: NXW-MOBYD-SLGD11
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two
conditions:
(1) This device may not cause harmful interference, and
(2) This device must accept any interference that may cause undesired operation.
Note
The manufacturer is not responsible for any radio or TV interference caused by unauthorized
changes and modifications to this equipment:
Such modifications could void the user's authority to operate the equipment.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC MOBY D and is the answer not in the manual?

Siemens SIMATIC MOBY D Specifications

General IconGeneral
BrandSiemens
ModelSIMATIC MOBY D
CategoryAccessories
LanguageEnglish

Related product manuals