Mobile data storage units
5.11 MDS D424
MOBY D
136 System Manual, 01/2010, J31069-D0147-A6-7618
5.11 MDS D424
5.11.1 Characteristics
MDS D424 Characteristics
Field of application Production and distribution logistics as well as in
assembly and production lines
Memory FRAM 2048 bytes gross
2000 bytes net
Read/write range See Chapter Field data (Page 33).
Mounting on metal Not possible:
Recommended distance from metal ≥ 25 mm
High resistance Can also be used in a harsh industrial environment
without problem
Standard Oriented according to ISO standard 15693
5.11.2 Ordering data
Table 5- 16 Ordering data of MDS D424
Order number
MDS D424 6GT2600-4AC00
5.11.3 Mounting on metal
Mounting on metal
0HWDO
'DWDPHPRU\
1RQPHWDO
K
h ≥ 25 mm
Figure 5-23 Mounting of the MDS D424 on metal with spacer