EasyManuals Logo
Home>Siemens>Accessories>SIMATIC MOBY D

Siemens SIMATIC MOBY D User Manual

Siemens SIMATIC MOBY D
350 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #141 background imageLoading...
Page #141 background image
Mobile data storage units
5.12 MDS D428
MOBY D
System Manual, 01/2010, J31069-D0147-A6-7618
141
5.12.3 Application example of MDS D428
0DLQILHOG
0RWRUEORFN
&RQYH\RUGLUHFWLRQ
0'6'
6/*
Figure 5-26 Application example
Table 5- 19 Field data MDS D428 - MOBY D-SLG
SLG D10/D10S
ANT D5
SLG D11/D11S
ANT D5
SLG D12/D12S
Operating distance (Sa) 0…120 0…70 0…40
Limit distance (Sg) 160 100 60
Transmission window
(L
x
/L
y
)
∅ 300 ∅ 280 100 / 60
Minimum distance from
MDS to MDS
≥ 800 ≥ 800 ≥ 300
All values are in mm

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC MOBY D and is the answer not in the manual?

Siemens SIMATIC MOBY D Specifications

General IconGeneral
BrandSiemens
ModelSIMATIC MOBY D
CategoryAccessories
LanguageEnglish

Related product manuals