Write/read devices with RS422 interface
7.2 SLG D10S basic unit
MOBY D
System Manual, 01/2010, J31069-D0147-A6-7618
177
Ambient temperature
ï‚· Operation
ï‚· Transport and storage
 -20 °C to +55 °C
 -25 °C to +70 °C
MTBF 7.5 x 10
4
hours
Degree of protection according to EN 60529 IP65 (UL: for indoor use only)
Shock resistant according to EN 60721-3-7
Class 7M2
Total shock response spectrum Type II
30 g
Vibration according to EN 60721-3-7 Class 7M2 1 g (9 to 200 Hz)/1.5 g (200 to 500 Hz)
Weight, approx. 3500 g
Approvals
ï‚· CE
ï‚· FCC
ï‚· IC
ï‚· Harmless to heart pacemakers
ï‚· UL 60950
7.2.4 FCC information
Siemens MOBY D SLG D10S
FCC ID: NXW-MOBYD-SLGD10
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two
conditions:
(1) This device may not cause harmful interference, and
(2) This device must accept any interference that may cause undesired operation.
Note
The manufacturer is not responsible for any radio or TV interference caused by unauthorized
changes and modifications to this equipment:
Such modifications could void the user's authority to operate the equipment.