Mobile data storage units
5.13 MDS D460
MOBY D
144 System Manual, 01/2010, J31069-D0147-A6-7618
5.13 MDS D460
5.13.1 Characteristics
MDS D460 Characteristics
Field of application Identification in small assembly lines
Memory FRAM 2048 bytes gross
2000 bytes net
Read/write range See Chapter Field data (Page 33).
Mounting on metal Not possible:
Recommended distance from metal ≥ 25 mm
High resistance Can also be used in a harsh industrial environment
Standard Oriented according to ISO standard 15693
5.13.2 Ordering data
Table 5- 21 Ordering data of MDS D460
Order number
MDS D460 6GT2600-4AB00