System integration
9.4 ASM 475
MOBY D
System Manual, 01/2010, J31069-D0147-A6-7618
253
9.4 ASM 475
9.4.1 Application area
The ASM 475 interface module can be inserted in SIMATIC S7-300 and ET 200M and can
be used for all MOBY systems.
As many as eight ASM 475 interface modules can be plugged into one SIMATIC S7-300
rack and operated. In a configuration with several racks (max. four), the ASM 475 can be
plugged into and operated on any rack. This means that as many as 32 ASMs can be
operated in the maximum configuration of a SIMATIC S7-300. The ASM can also be
operated in the ET 200M distributed I/O on PROFIBUS DP. Operation in an S7-400
environment is therefore problem-free. Up to 8 ASMs can be operated on each ET 200M.
Figure 9-16 ASM475 interface module
FC 45 with project example
You can load the FC with a project example from the corresponding subdirectory on the CD
RFID Systems Software & Documentation
using the "Dearchive file" function of SIMATIC
Manager. You will then find the project example in the S7PROJ directory of SIMATIC
Manager.
Directory in
RFID Systems Software & Documentation
SIMATIC Manager project name SIMATIC Manager path name
FC 45 MOBY FC45 Moby_f_l

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC MOBY D and is the answer not in the manual?

Siemens SIMATIC MOBY D Specifications

General IconGeneral
BrandSiemens
ModelSIMATIC MOBY D
CategoryAccessories
LanguageEnglish

Related product manuals