Planning the MOBY D system
4.3 Installation guidelines
MOBY D
System Manual, 01/2010, J31069-D0147-A6-7618
43
4.3.4 Influences affecting the transmission window
In general, the following points should be considered when mounting MOBY D components:
Flush-mounting of components in metal reduces the field data.
When working inside the transmission window, it should be ensured that no metal rails or
closed conductor loops protrude into the transmission field. They would impair the field
profile.
It is recommended that a test is performed in critical applications.
In order to ensure optimum field data even in the vicinity of metal, ANT D5 is calibrated at
the factory at a distance of 100 mm from metal (see the following tables). Therefore it
must always be operated at a distance of 100 mm from metal.
The impact of metal on the field data (Sg, Sa, Lx, Ly) is shown in tabular and graphical
format in this section.
The values in the tables describe field data reduction as a percentage (100% means no
impact).

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC MOBY D and is the answer not in the manual?

Siemens SIMATIC MOBY D Specifications

General IconGeneral
BrandSiemens
ModelSIMATIC MOBY D
CategoryAccessories
LanguageEnglish

Related product manuals