Page #172 background image
Write/read devices with RS422 interface
7.1 Overview SLG with RS 422 for SIMATIC S7 and PROFIBUS DP-V1
MOBY D
172 System Manual, 01/2010, J31069-D0147-A6-7618
Application area
The SLG D1xS provides inductive communication with the mobile data storage units (MDS)
and serial coupling to the interface modules (ASM).
A range of different SLGs are available for small, medium and large distances to the MDS
meeting all customer requirements.
SLG D10S with
ANT D5
ANT D6
ANT D10
SLG D11S with
ANT D2
ANT D5
SLG D12S with integral antenna
SLG D12S with integral antenna (plug-in version)
The rugged housing and high degree of protection (IP65) permit use even under the
toughest industrial conditions.
Design and function
The SLG implements the commands received from the interface module. These commands
and the data to be written or read are processed by a corresponding modulator/demodulator
circuit.
Communication between the MDS and SLG is performed over an inductive alternating field.
The transmittable quantity of information between SLG and MDS depends on:
The speed at which the MDS moves through the transmission window of the SLG
antenna
The length of the transmission window
The MDS type
Table 7- 1 Overview of SLG with RS 422 interface
SLG with ANT Operating
distance S
a
(depending on
MDS)
Limit distance
S
g
(depending on
MDS)
Temperature
range
(during
operation)
SLG dimensions
(L x W x H)
in mm
Antenna
dimensions
(L x W x H)
in mm
Degree
of
protecti
on
ANT D5 0 to 400 mm 480 mm -20 to +55 °C 320 x 145 x 100 340 x 325 x 38 IP65
ANT D6 0 to 550 mm 650 mm -20 to +55 °C 320 x 145 x 100 580 x 480 x 110 IP65
SLG D10S
ANT D10 0 to 400 mm 480 mm -20 to +55 °C 320 x 145 x 100 1150 x 365 x 115 IP65
ANT D2 35 to 70 mm 90 mm -20 to +70 °C 160 x 80 x 40 75 x 75 x 40 IP65 SLG D11S
ANT D5 0 to 300 mm 380 mm -20 to +55 °C 160 x 80 x 40 340 x 325 x 38 IP65
SLG D12S
1)
0 to 120 mm 160 mm -20 to +55 °C 160 x 80 x 40 - IP65
SLG D12S
(plug-in version)
1)
0 to 120 mm 160 mm -25 to +55 °C 160 x 80 x 40 - IP67
1)
Integral antenna

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC MOBY D and is the answer not in the manual?

Siemens SIMATIC MOBY D Specifications

General IconGeneral
BrandSiemens
ModelSIMATIC MOBY D
CategoryAccessories
LanguageEnglish

Related product manuals