Parameterizing Steps 08.2012
6SE7087-6QX70 (Version AN) Siemens AG
6-4 Compendium Motion Control SIMOVERT MASTERDRIVES
Parameter number Parameter name
P053 Parameterization enable
P696 SCB protocol
P700 SST bus address
P701 SST baud rate
P702 SST PKW number
P703 SST PZD number
P704 SST frame failure
Table 6-3 The factory setting is made via interface SCB2: Parameters that are not
changed by the factory setting either. None of the indices of the
parameters is changed.
Parameter number Parameter name
P053 Parameterization enable
P711 to P721 CB parameters 1 to 11
P722 CB/TB frame failure
P918 CB bus address
Table 6-4 The factory setting is made either via interface 1.CB/TB or 2.CB/TB:
Parameters that are not changed by the factory setting either. None of
the indices of the parameters is changed.
Select "Fixed settings" menu
P366 = ?
P970 = 0
Start parameter reset
0: Parameter reset
1: No parameter change
P060 = 2
Select desired factory setting
0: Standard
Note: This parameter was correctly set prior to delivery of
the unit and only needs to be changed in exceptional
cases.
P053 = 6
Grant parameter access
6: Parameter changes permitted via PMU and serial interface
SCom1 (OP1S and PC)
Unit carries out parameter
reset and then leaves the
"Fixed settings" menu.
Fig. 6-2 Sequence for parameter reset to factory setting