Communication / PROFIBUS 09.2008
6SE7087-6QX70 (Version AK) Siemens AG
8.2-46 Compendium Motion Control SIMOVERT MASTERDRIVES
8.2.5.3 CBP slots in Compact and chassis-type units with the CUs of function
classes FC (CU1), VC (CU2) or SC (CU3)
The adaption board with optional board
can be mounted in the electronics box in
1.B2 and/or 1.B3.
Adaption board
ADB
Optional board
CBP
Electronics box
+1.B1
+1.B3
+1.B2
Fig. 8.2-10 Electronics box with free slots (+1.B2 and +1.B3) and adaptation board with
CBP
On the adaptation board ADB (Order No. 6SX7010-0KA00), only one
CBP can be mounted in slot X198, i.e. at the BOTTOM.
If the CBP is mounted with adaptation board, the LBA (Local Bus
Adapter, LBA, Order No. 6SE7090-0XX84-4HA0) must first be mounted.
If only one optional board is used, it must always be inserted in slot
+1.B2 (on the RIGHT) in the electronics box.
If, in addition to the CBP, a technology board (T100 / T300 or T400) is
inserted in the electronics box, it must be inserted in slot +1.B2. In this
case, the CBP is inserted in slot +1.B3.
NOTE

Table of Contents

Other manuals for Siemens simovert masterdrives

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens simovert masterdrives and is the answer not in the manual?

Siemens simovert masterdrives Specifications

General IconGeneral
BrandSiemens
Modelsimovert masterdrives
CategoryDC Drives
LanguageEnglish

Related product manuals