Configuration and Connection Examples 12.2010
6SE7087-6QX70 (Version AM) Siemens AG
2-50 Compendium Motion Control SIMOVERT MASTERDRIVES
Parameter PFH value PL Comment
ACQUIRE 2.47 x 10
-8
/ h e Position switches –S4 and –S5
EVALUATE
2 x 5.4x10
-11
/ h
e
Safety switching devices -A2
and –A3
REACT
4.29 x 10
-8
/ h
e
Switching elements –K1, –K2,
–K3 and –K4
Total 8.59 x 10
-8
/ h e < 1x10
-6
/ h
The requirements regarding PL d with Category 3 for the
protective door safety function are thus fulfilled.
2.4.7.2 Supplementary safety function Emergency Stop
The drive must be safely brought to a standstill and switched off if the
Emergency Stop button is actuated.
The Emergency Stop button is actuated 1x per month.
This safety function can be assessed according to the same principles
described in subsection 2.4.7.1 "Protective door safety function".
However, the Emergency Stop button and the safety switching device
–A1 must be included in the calculation for this safety function. The
position switches for protective door monitoring play no role in the
Emergency Stop function..
Fig. 2-17 Block diagram of the supplementary safety function Emergency Stop
Check of the PFH
value of the safety
functions as a whole
Assumption

Table of Contents

Other manuals for Siemens simovert masterdrives

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens simovert masterdrives and is the answer not in the manual?

Siemens simovert masterdrives Specifications

General IconGeneral
BrandSiemens
Modelsimovert masterdrives
CategoryDC Drives
LanguageEnglish

Related product manuals