Communication / SIMOLINK 12.2010
6SE7087-6QX70 (Version AM) Siemens AG
8.3-26 Compendium Motion Control SIMOVERT MASTERDRIVES
The SL master uses the "intelligence" and the possibilities offered by
the open/closed-loop control system or the PC for configuring the task
table. The following SL masters are currently available:
• SIMOLINK module in SIMATIC FM458
• Expansion board ITSL in SIMADYN D
In accordance with the peer-to-peer functionality
8.3.13 Application with master/slave functionality
This configuration is not based on the principle of freely selectable data
transfer between MASTERDRIVES MC/VC units because control is
effected from a higher-level automation system.
SIMADYN D
SIEMENS
6SE 7016- 1EA3 0
WR 2,2 k W
Nr. 4 6732 1
SI MO VE R T SC
Transceiver
SIEMENS
6SE 7016- 1EA3 0
WR 2,2 k W
Nr. 4 6732 1
SI MO VE R T SC
Transceiver
SIEMENS
6SE 7016- 1EA3 0
WR 2,2 k W
Nr. 4 6732 1
SI MO VE R T SC
Transceiver
SIMATIC or SIMADYN
SIMOLINK
Master
Fig. 8.3-13 Application example of master/slave functionality
There is a SIMOLINK interface in the automation system which also
operates as a logical master in addition to the dispatcher function. This
means that the automation system dispatches a maximum of eight 32
bit data back to the master by overwriting received telegrams with the
dispatch information. This is the typical structure of data exchange
according to the master/slave principle.
NOTE
Transceiver
Principle