2.4.5.3 Check of the PFH value of the safety function as a whole
Parameter PFH value PL Comment
ACQUIRE 4.29 x 10
-8
/ h e Emergency Stop button –S3
EVALUATE 9.4 x 10
-10
/ h e Safety switching device –A1
REACT
4.29 x 10
-8
/ h
e
Switching elements –K1 and
-K2
Total
8.67 x 10
-8
/ h
e
< 1x10
-6
/ h
The requirements regarding PL d with Category 3 for the
supplementary safety function Emergency Stop are thus fulfilled.
2.4.6 Emergency Stop and protective door monitoring on a converter
STO
a) The drive is switched off safely when the protective door is opened.
b) The drive must be switched off safely by the supplementary safety
function Emergency Stop.
As a result of the risk assessment, the required performance level for
both safety functions has been defined as PLr = d.
The DC link must remain energized in normal operation when the
protective door is open.
Requirement

Table of Contents

Other manuals for Siemens simovert masterdrives

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens simovert masterdrives and is the answer not in the manual?

Siemens simovert masterdrives Specifications

General IconGeneral
BrandSiemens
Modelsimovert masterdrives
CategoryDC Drives
LanguageEnglish

Related product manuals