Engineering Information 06.2005
6SE7087-6QX70 (Version AE) Siemens AG
11-46 Compendium Motion Control SIMOVERT MASTERDRIVES
Unit rating [kW] Standard
Unit rating [kW] with F02 as add.
option
Rated output current
IUn [A]
Short-time/overload current
Imax. [A]
Rated DC link
current
IZKn [A]
Line current
(only for converters) [A]
Order No.
Converter
Order No.
Inverter
Total power loss
Converter [kW]
Total power loss
Inverter [kW]
Weight kg
Basic unit with F02 as additional
option
75
90 186 254 221 205 6SE7031–8EF70 6SE7031–8TF70 2.17 1.7 75
90 110 210 287 250 231 6SE7032–1EG70 6SE7032–1TG70 2.68 2.18 160
110 132 260 355 309 286 6SE7032–6EG70 6SE7032–6TG70 3.40 2.75 160
132 160 315 430 375 346 6SE7033–2EG70 6SE7033–2TG70 4.30 3.47 180
160 200 370 503 440 407 6SE7033–7EG70 6SE7033–7TG70 5.05 4.05 180
200 250 510 694 607 – – 6SE7035–1TJ70 – 5.8 350
200 250 510 694 607 561 6SE7035–1EK70 – 7.10 – 400
250 315 590 802 702 – – 6SE7036–0TJ70 – 6.6 350
250 315 590 802 702 649 6SE7036–0EK70 – 8.20 – 400
*400 690 938 821 – – 6SE7037–0TJ70 – 8,8 350
*400 690 938 821 759 6SE7037–0EK70 – 10.20 – 400
*500 860 1170 1023 – – 6SE7038–6TK70 – 11.9 520
*630 1100 1496 1310 – – 6SE7041–1TK70 – 13.4 520
*710 1300 1768 1547 – – 6SE7041–3TL70 – 14.5 625
* Performance extension: Only operable with P357 = 1 (max. 2.7 kHz)
(F02 as add. option is included)
Table 11-2 Overview of units which can be operated with F02 as an additional option
Overview