144
Handset Firmware Upgrade Configuration
The following table lists the parameters you can use to upgrade handset firmware.
Parameter
over_the_air.url <y0000000000xx>.cfg
Description
It configures the access URL of the handset firmware file.
Note: The priority of parameter “over_the_air.url is lower than “over_the_air.url.w56h”/over_the_air-
.url.w53h/“over_the_air.url.w52h”.
Permitted
Values
URL within 511 characters
Default
Blank
Web UI
Settings > Upgrade > Select and update handset firmware.
Parameter
over_the_air.url.w56h <y0000000000xx>.cfg
Description
It configures the access URL of the W56H handset firmware file.
Note: The priority of parameter “over_the_air.url.w56h” is higher than “over_the_air.url”.
Permitted
Values
URL within 511 characters
Default
Blank
Parameter
over_the_air.url.cp930w <y0000000000xx>.cfg
Description
It configures the access URL of the CP930W phone firmware file.
Note: The priority of parameter “over_the_air.url.cp930w is higher than “over_the_air.url”.
Permitted
Values
URL within 512 characters
Default
Blank
Parameter
over_the_air.handset_tip <y0000000000xx>.cfg
Description
It enables or disables to pop up a tip when upgrading the handset firmware from the provisioning
server.
Note: It works only if “over_the_air.base_trigger” and “over_the_air.handset_trigger” are set to 0 (Dis-
abled).
Permitted
Values
0-Disabled
1-Enabled, the handset will pop up the message “Handset has a new firmware, update now?”.
Default
1
Supported
Devices
All handsets except DD phones
Parameter
over_the_air.handset_trigger <y0000000000xx>.cfg
Description
It enables or disables to upgrade the handset firmware compulsively when the handset is registered
to a phone or turned on successfully.
It is only applicable when the current handset firmware is different from the one on the provisioning
server.
Permitted
Values
0-Disabled, if “over_the_air.handset_tip is set to 1 (Enabled), it will pop up a tip on the handset to
notify the user of firmware upgrade. If “over_the_air.handset_tip is set to 0, you may go to Settings >
Upgrade Firmware on the handset to trigger the upgrading manually.
1-Enabled, it will upgrade the handset firmware compulsively without a pop-up tip on the handset.

Table of Contents

Other manuals for Yealink SIP-T41S

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Yealink SIP-T41S and is the answer not in the manual?

Yealink SIP-T41S Specifications

General IconGeneral
MountingDesk/Wall
Handset typeWired handset
Product typeIP Phone
Product colorBlack
Keypad illuminationYes
Wi-FiNo
Networking standardsIEEE 802.3af
Ethernet LAN data rates10, 100 Mbit/s
Ethernet LAN interface typeFast Ethernet
Supported network protocolsSIP v1, SIP v2, LLDP/CDP/DHCP, OpenVPN, IEEE802.1X, IPv6, FTP/TFTP/HTTP/HTTPS
Volume controlDigital
Number of programmable keys6
Lines quantity6 lines
Phonebook capacity1000 entries
Dual-Tone Multi-Frequency (DTMF) modesIn-band, Out-of band, SIP info
Input frequency50/60 Hz
AC adapter input voltage100 - 240 V
AC adapter output current1.2 A
AC adapter output voltage5 V
Display diagonal2.7 \
Display resolution192 x 64 pixels
Operating temperature (T-T)-10 - 50 °C
Operating relative humidity (H-H)10 - 95 %
Voice codecsCNG, G.711Mu, G.711a, G.723.1, G.726, G.729ab, VAD, iLBC
CertificationCE
Cables includedLAN (RJ-45)
Number of handles included1 pc(s)
Harmonized System (HS) code85171800
Weight and Dimensions IconWeight and Dimensions
Depth189 mm
Width212 mm
Height175 mm
Package depth223 mm
Package width246 mm
Package height120 mm