185
Voice Quality Reports Configuration
The following table lists the parameters you can use to configure the service quality reports.
Parameter
phone_setting.vq_rtcpxr.session_report.enable <y0000000000xx>.cfg
Description
It enables or disables the phone to send a session quality report to the central report collector at the
end of each call.
Permitted
Values
0-Disabled
1-Enabled
Default
0
Web UI
Settings > Voice Monitoring > VQ RTCP-XR Session Report
Parameter
phone_setting.vq_rtcpxr.interval_report.enable <y0000000000xx>.cfg
Description
It enables or disables the phone to send an interval quality report to the central report collector peri-
odically throughout a call.
Permitted
Values
0-Disabled
1-Enabled
Default
0
Web UI
Settings > Voice Monitoring > VQ RTCP-XR Interval Report
Parameter
phone_setting.vq_rtcpxr_interval_period <y0000000000xx>.cfg
Description
It configures the interval (in seconds) for the phone to send an interval quality report to the central
report collector periodically throughout a call.
Note: It works only if “phone_setting.vq_rtcpxr.interval_report.enable is set to 1 (Enabled).
Permitted
Values
Integer from 5 to 20
Default
20
Web UI
Settings > Voice Monitoring > Period for Interval Report
Parameter
phone_setting.vq_rtcpxr_moslq_threshold_warn-
ing
<y0000000000xx>.cfg
Description
It configures the threshold value of listening MOS score (MOS-LQ) multiplied by 10. The threshold
value of MOS-LQ causes the phone to send a warning alert quality report to the central report col-
lector.
For example, a configured value of 35 corresponds to the MOS score 3.5. When the MOS-LQ value
computed by the phone is less than or equal to 3.5, the phone will send a warning alert quality report
to the central report collector. When the MOS-LQ value computed by the phone is greater than 3.5, the
phone will not send a warning alert quality report to the central report collector.
If it is set to blank, warning alerts are not generated due to MOS-LQ.
Permitted
Values
Integer from 15 to 40
Default
Blank
Web UI
Settings > Voice Monitoring > Warning Threshold for Moslq
Parameter
phone_setting.vq_rtcpxr_moslq_threshold_critical <y0000000000xx>.cfg
Description
It configures the threshold value of listening MOS score (MOS-LQ) multiplied by 10. The threshold
value of MOS-LQ causes the phone to send a critical alert quality report to the central report collector.
For example, a configured value of 28 corresponds to the MOS score 2.8. When the MOS-LQ value
computed by the phone is less than or equal to 2.8, the phone will send a critical alert quality report to

Table of Contents

Other manuals for Yealink SIP-T41S

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Yealink SIP-T41S and is the answer not in the manual?

Yealink SIP-T41S Specifications

General IconGeneral
MountingDesk/Wall
Handset typeWired handset
Product typeIP Phone
Product colorBlack
Keypad illuminationYes
Wi-FiNo
Networking standardsIEEE 802.3af
Ethernet LAN data rates10, 100 Mbit/s
Ethernet LAN interface typeFast Ethernet
Supported network protocolsSIP v1, SIP v2, LLDP/CDP/DHCP, OpenVPN, IEEE802.1X, IPv6, FTP/TFTP/HTTP/HTTPS
Volume controlDigital
Number of programmable keys6
Lines quantity6 lines
Phonebook capacity1000 entries
Dual-Tone Multi-Frequency (DTMF) modesIn-band, Out-of band, SIP info
Input frequency50/60 Hz
AC adapter input voltage100 - 240 V
AC adapter output current1.2 A
AC adapter output voltage5 V
Display diagonal2.7 \
Display resolution192 x 64 pixels
Operating temperature (T-T)-10 - 50 °C
Operating relative humidity (H-H)10 - 95 %
Voice codecsCNG, G.711Mu, G.711a, G.723.1, G.726, G.729ab, VAD, iLBC
CertificationCE
Cables includedLAN (RJ-45)
Number of handles included1 pc(s)
Harmonized System (HS) code85171800
Weight and Dimensions IconWeight and Dimensions
Depth189 mm
Width212 mm
Height175 mm
Package depth223 mm
Package width246 mm
Package height120 mm