Network Configurations
67
TR-069 Device Management
TR-069 is a technical specification defined by the Broadband Forum, which defines a mechanism that encom-
passes secure auto-configuration of a CPE (Customer-Premises Equipment), and incorporates other CPE man-
agement functions into a common framework. TR-069 uses common transport mechanisms (HTTP and HTTPS) for
communication between CPE and ACS (Auto Configuration Servers). The HTTP(S) messages contain XML-RPC
methods defined in the standard for configuration and management of the CPE.
For more information on TR-069, refer to Yealink TR-069 Technote.
Topics
Supported RPC Methods
TR-069 Configuration
Supported RPC Methods
The following table provides a description of RPC methods supported by the phones.
RPC Method Description
GetRPCMethods This method is used to discover the set of methods supported by the CPE.
SetParameterValues This method is used to modify the value of one or more CPE parameters.
GetParameterValues This method is used to obtain the value of one or more CPE parameters.
GetParameterNames This method is used to discover the parameters accessible on a particular CPE.
GetParameterAttributes This method is used to read the attributes associated with one or more CPE parameters.
SetParameterAttributes This method is used to modify attributes associated with one or more CPE parameters.
Reboot This method causes the CPE to reboot.
Download
This method is used to cause the CPE to download a specified file from the designated loc-
ation.
File types supported by the phones are:
l Firmware Image
l Configuration File
Upload
This method is used to cause the CPE to upload a specified file to the designated location.
File types supported by the phones are:
l Configuration File
l Log File
ScheduleInform
This method is used to request the CPE to schedule a one-time Inform method call (sep-
arate from its periodic Inform method calls) sometime in the future.
FactoryReset This method resets the CPE to its factory default state.
TransferComplete
This method informs the ACS of the completion (either successful or unsuccessful) of a file
transfer initiated by an earlier Download or Upload method call.
AddObject This method is used to add a new instance of an object defined on the CPE.
DeleteObject This method is used to remove a particular instance of an object.
TR-069 Configuration
The following table lists the parameters you can use to configure TR-069.

Table of Contents

Other manuals for Yealink SIP-T41S

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Yealink SIP-T41S and is the answer not in the manual?

Yealink SIP-T41S Specifications

General IconGeneral
MountingDesk/Wall
Handset typeWired handset
Product typeIP Phone
Product colorBlack
Keypad illuminationYes
Wi-FiNo
Networking standardsIEEE 802.3af
Ethernet LAN data rates10, 100 Mbit/s
Ethernet LAN interface typeFast Ethernet
Supported network protocolsSIP v1, SIP v2, LLDP/CDP/DHCP, OpenVPN, IEEE802.1X, IPv6, FTP/TFTP/HTTP/HTTPS
Volume controlDigital
Number of programmable keys6
Lines quantity6 lines
Phonebook capacity1000 entries
Dual-Tone Multi-Frequency (DTMF) modesIn-band, Out-of band, SIP info
Input frequency50/60 Hz
AC adapter input voltage100 - 240 V
AC adapter output current1.2 A
AC adapter output voltage5 V
Display diagonal2.7 \
Display resolution192 x 64 pixels
Operating temperature (T-T)-10 - 50 °C
Operating relative humidity (H-H)10 - 95 %
Voice codecsCNG, G.711Mu, G.711a, G.723.1, G.726, G.729ab, VAD, iLBC
CertificationCE
Cables includedLAN (RJ-45)
Number of handles included1 pc(s)
Harmonized System (HS) code85171800
Weight and Dimensions IconWeight and Dimensions
Depth189 mm
Width212 mm
Height175 mm
Package depth223 mm
Package width246 mm
Package height120 mm

Related product manuals