Filtration elements cleanin
g
Draining the condensate from air collector
Air condition maintenance
Regenerate filtration elements of the cab depending on the
degree of clogging:
- by dusting
- by blowing with compressed air
Check clogging daily. Replace strongly polluted filters.
Tractor's safety cab is not equipped with special
filters for air sucked into the cab.
It does not protect operators against the effects of
aerosols and other harmful substances!
NM13N110
Air collector is placed on the right side of the tractor under
the cab. Draining the condensate from air collectorto be
done by deviation of venting valve by pulling a ring. Valve
is located on the bottom part of air collector.
NM13N074
The main element of air condition system
maintenance is cleaning air condition condenser (is
p
laced in front of en
g
ine radiator
).
Clogged air condition condenser decreases not only
the efficiency of cooling system but also the
efficiency of engine cooling.
Open the bonnet, demount the nut (1) and protrude the
radiator to the side and blow with compressed air or wash
with pressed water (against the direction of tractor drive)
.
Slide the radiator back in and attach properly. Mind proper
conducting of hoses to oil radiator.
E740
MAINTENANCE INSTRUCTIONS
115

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Zetor MAJOR CL and is the answer not in the manual?

Zetor MAJOR CL Specifications

General IconGeneral
BrandZetor
ModelMAJOR CL
CategoryTractor
LanguageEnglish

Related product manuals