Rev D System Management Module 2 (SMM-2) 7-5
Operation of Auto Config Modules
The operation of the Auto Config modules consists of the following three phases (See
Figure 5.1 on page 5-7):
Learning — Occurs immediately after a management module boots up and
determines the shelf baseline by querying every installed module for its
configurable parameters. During this phase, the Status LED of the management
module and the Status LED of the module installed in slot 1 will both blink to
indicate the management module is obtaining the configurable parameters. Next,
the management module will sequentially step from slot 2 through slot 10, followed
by the power supplies (slots 11 and 12). The learning process is complete when the
Status LEDs on all application modules and the management module are no longer
blinking. This process results in the management module configuration table stored
in the new flash memory.
CHP-MW0x 2.015 4.020 2.3.0.0
CHP-MWVx 2.006 4.024 2.4.0.0
CHP-MWXx 2.006 4.024 2.4.0.0
CHP-OPM1 latest not
supported
not
supported
CHP-OPTSWITCH latest not
supported
2.3.0.0
CHP-R2RR 2.000 4.000 2.3.0.0
CHP-R2RRFF latest not
supported
2.4.0.0
CHP-R2RRXF latest not
supported
2.6.0.0
CHP-R2RRXR latest not
supported
2.6.0.0
CHP-R4RRXF latest 4.000 2.5.0.0
CHP-RFRX latest 4.000 2.4.0.0
CHP-RTX3 latest 4.000 2.4.0.0
CHP-RTX5 latest 4.000 2.4.0.0
CHP-Sxxx 1.003 5.008 2.5.0.0
CHP-XMOD latest not
supported
2.4.0.0
* For best performance, use CMM-1 version 5.013 or later.
Table 7.1 Auto Config Supported Application Modules (contd)
Application Module First Supported Firmware Version

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Arris CHP Max5000 and is the answer not in the manual?

Arris CHP Max5000 Specifications

General IconGeneral
Product TypeMulti-service Platform
Input Impedance75 ohms
Forward Path Bandwidth54-1002 MHz
ManagementSNMP
Frequency Range Downstream54-1002 MHz
Modulation DownstreamQAM
Modulation UpstreamQAM
Operating Temperature0°C to 50°C
Dimensions19"

Summary

CHP Max5000 Chassis (Rear Fiber Version) - Equipment Description and Installation

CHP Max5000 Chassis Equipment Description

Describes the CHP Max5000 chassis, including its mounting, modules, fans, and cooling mechanisms.

CHP Chassis Installation Procedures

Provides step-by-step instructions for installing the CHP chassis into a standard EIA 19-inch rack.

CHP Max AC Power Supply - Description, Installation, and Specifications

CHP Max AC Power Supply Equipment Description

Describes the CHP Max AC power supply, its models, features, and power output capabilities.

Installing and Removing the AC Power Supply Module

Provides instructions for installing and removing the AC Power Supply module, including hot-swapping.

Updating AC Power Supply Module Firmware

Covers procedures for updating the AC power supply module's microcontroller firmware using Craft Management Software.

CHP Max DC Power Supply - Description, Installation, and Specifications

CHP Max DC Power Supply Equipment Description

Describes the CHP Max DC power supply, its models, features, and power output capabilities.

Installing and Removing the DC Power Supply Module

Provides instructions for installing and removing the DC Power Supply module, including connections.

Updating DC Power Supply Module Firmware

Covers procedures for updating the DC power supply module's firmware using Craft Management Software.

CHP Max Element Management Modules (CMM, CMM-1, SMM, SMM-1)

Installation and Replacement of CMM or SMM Modules

Provides instructions for installing and replacing CMM or SMM modules in the chassis.

Management Module Configuration and Password Reset

Covers configuration steps, network cabling, IP addressing, and password reset procedures.

Updating CHP-CMM and SMM/SMM-1 Firmware

Details procedures for updating the microcontroller firmware for CMM and SMM modules.

System Management Module 2 (SMM-2) - Features and Configuration

SMM-2 Installation and Communication Connections

Covers SMM-2 installation, network information, and connection methods (TELNET, USB).

Related product manuals