6.3 Replacing the Power Supply Module
The procedure below describes how to replace the Power Supply module.
To replace a faulty Power Supply module:
1. Remove the faulty Power Supply module:
a. Using a Philips screwdriver, unfasten the two screws located on the module.
b. Press the red ejector buttons on the module's black ejector/injector latches.
c. Pull on the ejector/injector latches and then gently ease the module out of the slot.
2. Insert the replacement Power Supply module:
a. With the black ejector/injector latches in the open (pulled out) position, align the
module's edges with the groves inside the slot.
b. Gently ease the module (using your thumbs to push the module) into the slot until
the module is flush with the chassis.
c. Press the module's black ejector/injector latches inward, toward the middle until
you hear a click.
d. Secure the module to the chassis by fastening the two screws (using a Philips
screwdriver) located on the module.

Table of Contents

Other manuals for AudioCodes Mediant 3000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the AudioCodes Mediant 3000 and is the answer not in the manual?

AudioCodes Mediant 3000 Specifications

General IconGeneral
BrandAudioCodes
ModelMediant 3000
CategoryGateway
LanguageEnglish

Related product manuals