Trouble Shooting Information for C7000VP series
2.12 Noise occurred at operating the refresh roller -> New item
Description
Noise occurs when driving the refresh roller.
Cause
The screw that secures the roll retaining plate (FC7-4948-000) at the pressure assembly of the
refresh roller loosens and there generates a state of insufficient pressuring of the refresh roller
against the fixing roller; the refresh roller is driven with insufficient gear engagement for driving
the refresh roller.
Field Remedy
Tighten the screw loosened as described above.
The roll retaining plate may have been deformed.
In this case, replace the part.
(Reference)
Change into the locking screw (FU5-9235-000) is planned.
When the parts are prepared, Service Information will be issued.