Enter/Exit Programming Mode
110
PowerScan™ PD9130/PBT9100/PM9100
Code 128 Check Character Transmission
Enable this option to transmit the check character along with Code 128 bar
code data.
DEFAULT
Code 128 Check Character Transmission = Don’t Send
Code 128 Check Character Transmission = Send
Code 128 Function Character Transmission
Enables/disables transmission of Code128 function characters 1, 2, 3, and
4.
DEFAULT
Code 128 Function Character Transmission = Don’t Send
Code 128 Function Character Transmission = Send