Enter/Exit Programming Mode
198
PowerScan™ PD9130/PBT9100/PM9100
BC412 Set Length 1
This feature specifies one of the bar code lengths for BC412 Length Control.
Length 1 is the minimum label length if in Variable Length Mode, or the first
fixed length if in Fixed Length Mode. Length includes
the bar code’s check
and data characters. The length can be set from 2 to 50 characters.
Table 16 provides some examples for setting Length 1. See page 297 for
detailed instructions on setting this feature.
Table 24. BC412 Length 1 Setting Examples
STEP ACTION EXAMPLES
1
Desired Setting (pad with
leading zeroes)
02 Characters 07 Characters 15 Characters 50 Characters
2 Scan ENTER/EXIT PROGRAMMING MODE
3 Scan SELECT CODE 11 LENGTH 1 SETTING
4
Scan Two Characters From
Appendix D, Keypad
‘0’ and ‘2’ ‘0’ and ‘7’ ‘1’ and ‘5’ ‘5’ AND ‘0’
5 Scan ENTER/EXIT PROGRAMMING MODE
Select BC412 Length 1 Setting
To configure this feature, scan the ENTER/EXIT
bar code above, then the bar code at left fol-
lowed by digits from the Alphanumeric charac-
ters in
Appendix D, Keypad
representing your
desired character(s). End by scanning the
ENTER
/EXIT bar code again.
Make a mistake? Scan the CANCEL bar code to
abort
and not save the entry string. You can
then start again at the beginning.
CANCEL
DEFAULT
04 = Length 1 is 4 Characters