ENTER/EXIT PROGRAMMING MODE ETHERNET INTERFACE
88
POWERSCAN™ PD/PM/PBT9600
Subnet Mask
The subnet mask number is combined with the IP address number to identify which net-
work segment the CM968x is on.
A subnet mask is a 32-bit number that is composed by using four numbers from 0
through 255, separated by periods. Typically, default subnet mask numbers use either 0
or 255 as values (such as 255.255.255.0), but other number values can appear.
To connect the device to an existing LAN, specify the Subnet Mask that the LAN uses.
Gateway Address
A gateway is a router that connects separate IP network segments. For example, a net-
work segment might need a gateway to connect it to another network segment, a wide
area network (WAN), or to the Internet.
This feature specifies the address of a local IP router on the same network as the
CM968x, used to forward traffic to destinations beyond the local network. The value in
each field must be a number from 0 through 255.
Subnet Mask
$CETSM
To configure, scan the ENTER/EXIT PROGRAMMING
MODE bar code above, then the bar code at left fol-
lowed by 8 digits (in hex) from the Alphanumeric
characters in Appendix G, Keypad representing your
desired character(s). End by scanning the ENTER/
EXIT bar code.
Make a mistake? Scan the CANCEL bar code to abort
and not save the entry string. You can then start
again at the beginning.
CANCEL
FFFFFF00 = (hex) 192.168.187.31
Gateway Address
$CETGA
To configure, scan the ENTER/EXIT PROGRAMMING
MODE bar code above, then the bar code at left fol-
lowed by 8 digits (in hex) from the Alphanumeric
characters in Appendix G, Keypad representing your
desired character(s). End by scanning the ENTER/
EXIT bar code.
Make a mistake? Scan the CANCEL bar code to abort
and not save the entry string. You can then start
again at the beginning.
CANCEL
C0A8BBFE = (hex) 192.168.187.254

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Datalogic PowerScan Series and is the answer not in the manual?

Datalogic PowerScan Series Specifications

General IconGeneral
BrandDatalogic
ModelPowerScan Series
CategoryBarcode Reader
LanguageEnglish

Related product manuals