EasyManuals Logo
Home>Datalogic>Barcode Reader>PowerScan Series

Datalogic PowerScan Series User Manual

Datalogic PowerScan Series
411 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #332 background imageLoading...
Page #332 background image
REFERENCES
316
POWERSCAN™ PD/PM/PBT9600
RS-232/USB COM PARAMETERS
Intercharacter Delay
This parameter specifies the intercharacter delay between the end of one character and
the beginning of the next. The delay can be set within a range of zero (0) to 990 millisec-
onds in 10ms increments. A setting of zero specifies no delay.
To set the delay:
1. Determine the desired setting in milliseconds.
2. Divide the desired setting by 10 (setting is in 10ms increments). Pad the result
with leading zeroes to yield two digits. For example: 0 = 00, 5 = 05, 20 = 20, etc.
3. Scan the ENTER/EXIT PROGRAMMING MODE bar code to enter Programming
Mode.
4. Go to
page 50 and scan the bar code: SELECT INTERCHARACTER DELAY SETTING.
5. Scan the appropriate two digits from the keypad in
Appendix G, that represent the
duration which was determined in the steps above. You will hear a two-beep indi-
cation after the last character.
6. Scan the ENTER/EXIT PROGRAMMING MODE bar code to exit.
This completes the procedure. See the following table for examples of how to set this
feature.
Table 10 - Intercharacter Delay Setting Examples
NOTE: If you make a mistake before the last character, scan the CANCEL
bar code to abort and not save the entry string. You can then start again at
the beginning.
STEP ACTION EXAMPLES
1 Desired Setting
50ms 150ms 600ms 850ms
2
Divide by 10 (pad with leading
zeroes to yield two-digits)
05 10 60 85
3 Scan ENTER/EXIT PROGRAMMING MODE
4 Scan SELECT INTERCHARACTER DELAY SETTING
5
Scan two characters from
Appendix G
‘0’ and ‘5’ ‘1’ and 5’ ‘6’ and ‘0’ 8’ and ‘5’
6 Scan ENTER/EXIT PROGRAMMING MODE

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Datalogic PowerScan Series and is the answer not in the manual?

Datalogic PowerScan Series Specifications

General IconGeneral
BrandDatalogic
ModelPowerScan Series
CategoryBarcode Reader
LanguageEnglish

Related product manuals