EasyManuals Logo

Dell EMC PowerEdge MX740c User Manual

Dell EMC PowerEdge MX740c
136 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #125 background imageLoading...
Page #125 background image
Temperature Specications
Maximum temperature gradient (operating and storage) 20°C/h (68°F/h)
Table 19. Relative humidity specications
Relative humidity Specications
Storage 5% to 95% RH with 33°C (91°F) maximum dew point. Atmosphere must be
noncondensing always.
Operating 10% to 80% relative humidity with 29°C (84.2°F) maximum dew point.
Table 20. Maximum vibration specications
Maximum vibration Specications
Operating 0.26 G
rms
at 5 Hz to 350 Hz (all operation orientations).
Storage 1.87 G
rms
at 10 Hz to 500 Hz for 15 min (all six sides tested).
Table 21. Maximum shock specications
Maximum shock Specications
Operating Six consecutively executed shock pulses in the positive and negative x, y,
and z axes of 6 G for up to 11 ms.
Storage Six consecutively executed shock pulses in the positive and negative x, y,
and z axes (one pulse on each side of the system) of 71 G for up to 2 ms.
Table 22. Maximum altitude specications
Maximum altitude Specications
Operating
3048 m (10,000 ft)
Storage 12,000 m (39,370 ft)
Table 23. Operating temperature derating specications
Operating temperature derating Specications
Up to 35°C (95°F) Maximum temperature is reduced by 1°C/300 m (1°F/547 ft) above 950 m
(3,117 ft).
35°C to 40°C (95°F to 104°F) Maximum temperature is reduced by 1°C/175 m (1°F/319 ft) above 950 m
(3,117 ft).
40°C to 45°C (104°F to 113°F) Maximum temperature is reduced by 1°C/125 m (1°F/228 ft) above 950 m
(3,117 ft).
Particulate and gaseous contamination specications
The following table denes the limitations that help avoid any equipment damage or failure from particulates and gaseous contamination . If
the levels of particulates or gaseous pollution exceed the specied limitations and result in equipment damage or failure, you may must
rectify the environmental conditions. Remediation of environmental conditions is the responsibility of the customer.
Technical
specications 125

Table of Contents

Other manuals for Dell EMC PowerEdge MX740c

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dell EMC PowerEdge MX740c and is the answer not in the manual?

Dell EMC PowerEdge MX740c Specifications

General IconGeneral
BrandDell EMC
ModelPowerEdge MX740c
CategoryServer
LanguageEnglish

Related product manuals