E1SL 16 532258 04 - Rev. E
Translation of the original instructions
EN GL IS H
BASIC Function
Default
C1
INPUT I1 (J21) configuration The contact logic can be programmed from the SDK EVO (section § Configurable inputs).
1
no = input not enabled
1 = External Opening (NO)
4 = Internal Opening (NO)
7 = Automatic Opening (NO)
8 = Semi-Automatic Opening (NO)
9 = Pharmacy Open (NOT for SF1400 and GBF1500) (NO)
10 = KEY (NO)
11 = Partial Open (NOT for SF1400 and GBF1500) (NO)
20 = Closing Safety (NC)
21 = Opening Safety (NC)
23 = Safety STOP (NC)
24 = Closing Safety EXT (NC)
25 = Closing Safety INT (NC)
30 = Emergency Opening (NC)
31 = Emergency Opening with memory (NC)
32 = Emergency STOP (NC)
33 = Emergency STOP with memory (NC)
34 = Emergency Closing (NC)
35 = Emergency Closing with memory (NC)
37 = Emergency Break OUT for APN (NC)
40 = operating mode OPEN (NO)
41 = operating mode EXIT ONLY (NO)
42 = operating mode ENTRY ONLY (NO)
43 = operating mode NIGHT-TIME (NO)
44 = operating mode MANUAL (NO)
45 = operating mode PARTIAL (NOT for SF1400 and GBF1500) (NO)
46 = operating mode INTERLOCK (NO)
47 = operating mode AUTO MANUAL (NO)
60 = TIMER
61 = RESET
1F
INPUT I1 TEST Displayed only if the input is configured as Safety (
C1 = 20 or 21 or 23 or 24 or 25)
Y = TEST enabled , no = TEST not enabled
no
C2
INPUT I2 (J21)configuration (see options
C1)
4
2F
INPUT I2 TEST Displayed only if the input is configured as Safety (
C2 = 20 or 21 or 23 or 24 or 25)
Y = TEST enabled , no = TEST not enabled
no
C3
INPUT I3 (J21) configuration (see options
C1)
10
3F
INPUT I3 TEST Displayed only if the input is configured as Safety (
C3 = 20 or 21 or 23 or 24 or 25)
Y = TEST enabled , no = TEST not enabled
no
C4
INPUT I4 (J21) configuration (see options
C1)
7
4F
INPUT I4 TEST Displayed only if the input is configured as Safety (
C4 = 20 or 21 or 23 or 24 or 25)
Y = TEST enabled , no = TEST not enabled
no
PF
PARTIAL PHARMACY - NOT displayed for SF1400 (
CF= 4) or for GBF1500 (CF= 5) - Displayed if a configurable input is pharmacy
OPEN.
595 % Adjustment step = 5%
20
St
Exit PROGRAMMING Allows you exit from programming and decide whether to save the changes.
Y = save , no = do not save
Press the F button to confirm. After exit, the display shows automation status:
Y
00 CLOSED
01 OPENING
02 OPEN
03 in PAUSE
04 in NIGHT PAUSE
05 CLOSING
06 OPEN or STOPPED or CLOSED in EMERGENCY
07 in MANUAL operating mode
08 in NIGHT-TIME operating mode
10 System TEST in progress
11 STOPPED
12 safeties TEST in progress
13 Door ERROR (Press + and
-
simultaneously to display the
active ERROR)
LO-L2 SETUP in progress - phases LO, L1, L2
.
in SLEEP mode (flashing dot)

Table of Contents

Other manuals for FAAC SDK EVO

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the FAAC SDK EVO and is the answer not in the manual?

FAAC SDK EVO Specifications

General IconGeneral
BrandFAAC
ModelSDK EVO
CategoryControl Unit
LanguageEnglish

Related product manuals