E1SL 20 532258 04 - Rev. E
Translation of the original instructions
EN GL IS H
at least one sensor is released).
PARTIAL PHARMACY
- from Board Advanced Programming:
PF
- from SDK EVO: /PROGRAMMING/MISCELLANEUS/PARTIAL PHARMACY
NIGHT-TIME MODE DELAY
- from Board Advanced Programming:
nd
- from SDK EVO: /PROGRAMMING/TIMING/NIGHT SENSOR DELAY
7.11 DATE AND TIME
- from SDK EVO: /PROGRAMMING/DATE/TIME…
…SET DATE DD : MM
…SET TIME HH : mm
7.12 COUNTERS
CYCLE COUNTER  SCHEDULED MAINTENANCE
The SDK EVO can be used to enable the cycle counter and issue a
maintenance request according to the number of cycles carried out
or on a set date.
- from SDK EVO: /COUNTERS/CYCLES COUNT
…CYCLES NUMBER displays the number of cycles carried out, divided into ABSOLUTE
(NOT resettable) and RELATIVE cycles.
…MAINTENANCE enter the TECHNICIAN PSW and confirm.
go to MAINTENANCE CYCLES select: DISABLED or ENABLED and specify the number
of cycles for maintenance (step 10000, maximum 1000000) and confirm.
go to MAINTENANCE DATE select: DISABLED or ENABLED and set the date:
00/00/00
If both options are enabled, a maintenance request is issued when the first event
is reached (CYCLES or DATE).
…CYCLES RESET (TECHNICIAN PSW required) To reset the RELATIVE cycles counter,
confirm with OK. The ABSOLUTE cycles counter can only be reset using the Restoring
Factory Defaults procedure (§ relative sections).
SAFE FLOW
This function counts the people entering/leaving the premises for
capacity and queue management.
SDK EVO allows you to enable the function and to set the maximum
number of people allowed in. The count is displayed in relation to
the maximum programmed number in place of the date on the HOME
PAGE of the SDK EVO.
The count is carried out in AUTOMATIC and DOOR OPENED mode and
is zeroed when the door is put into MANUAL or NIGHT mode.
- from SDK EVO: /COUNTERS /SAFE FLOW
…FUNCTION select:
DISABLED = SAFE FLOW disabled
PEOPLE IN AUTO = enables counting and alarm. Alarm (40) is triggered when the
maximum number of people allowed is reached.
PEOPLE IN EXIT ONLY = enables counting and alarm. Alarm (40) is triggered when
the maximum number of people allowed is reached and the door does not allow people
to enter until the number of people in the premises falls below the set threshold.
…PEOPLE IN NUMBER sets the number of people allowed in (1…1000)
…PEOPLE IN UPDATE it allows the number of people in the premises (0 ... 1000) to
be corrected manually if necessary
NOTE: In an INTERCOM network (see Section § INTERCOM) the SAFE FLOW (PEOPLE IN
NUMBER, PEOPLE IN UPDATEFUNCTION) has to be programmed on the MASTER unit.
Then SAFE FLOW can also be enabled on the individual SLAVE boards via the PEOPLE
IN SLAVE parameter, displayed only on the SLAVE boards.
i
For the connections, configurations and devices required, see the
SAFE FLOW instructions.
7.13 TIMER
The TIMER function allows the operating mode of the automation
to be activated for programmed time bands. The operating mode
activated automatically by the TIMER cannot be changed manually,
unless you disable the TIMER.
Programming is carried out via the SDK EVO, it requires a clock bat-
tery to be installed on board E1SL (2) and the date and time to
be set correctly.
Programming can be done by day of the week (WEEKLY) and/or by cal-
endar date (JOLLY), e.g: for holidays, company closure... If both have
been programmed, in the event of an overlap, the JOLLY has priority.
A TIME BAND is programmed with:
- START time - END time (HH:mm)
- Operating mode
TIMER operating mode
0 NO FUNCTION
1 AUTO BIDIR (auto bidir total)
2 AUTO OUT (automatic exit only total)
3 AUTO BIDIR PARTIAL
4 AUTO OUT PARTIAL (automatic exit only partial)
5 TOTALLY OPEN
6 PARTIAL OPEN
7 AUTO IN (automatic entry only total)
8 AUTO IN PARTIAL (automatic entry only partial)
9 NIGHT (night total)
10 PARTIAL NIGHT
11 INTERLOCK (INTERLOCK bidirectional total)
12 INTERLOCK OUT (INTERLOCK exit only total)
13 INTERLOCK IN (INTERLOCK entry only total)
14 AUTO MANUAL (auto manual total)
1 or more TIME BANDS can be programmed (max 6) in 24 h.
When it exits from a programmed TIME BAND, if there is no subsequent
time band, the automation goes into AUTOMATIC TWO-DIRECTIONAL
TOTAL mode. Outside of the programmed time bands, the Operating
mode can be changed manually (from a Configured input or Func-
tion selector).
WEEKLY PROGRAMMING
Program the required days with the required time bands. To quickly
program one or more time bands for a group of days, program the
group MON - SUN or MON - FRI. Next, each time band can be repro-
grammed for a single day.
/TIMER…
…MONDAY…SUNDAY/MON-SUN/MON-FRI Select the day or group of days
…SLOT1…SLOT6 Select the time band
…FUNCTION: 0…14 Assign the operating mode from the TIMER
…BEGINNING 00:00 Set the TIME SLOT start time.
…END 00:00 Set the TIME SLOT end time.
If you are programming a group of days, after entering the END time of the time band,
the following question appears:
…DO YOU WANT TO APPLY MON - FRI ? OK
Carry out the same procedure for any other time bands. DO NOT pro-
gram overlapping time bands. Complete the weekly programming
for all the required days.
JOLLY PROGRAMMING
Program the JOLLY time bands. The JOLLY programming must be
applied to the dates specified in JOLLY SLOTS.
A JOLLY SLOT is defined by the START and END date of the slot. A
maximum of 12 JOLLY SLOTS can be programmed. A slot consist-
ing of one day has the same start and end date. A slot consisting
of several days cannot extend beyond December 31st. E.g. the
period from December 25th to January 6th is covered by two
slots: 25…31/12 + 01…06/01.
/TIMER…

Table of Contents

Other manuals for FAAC SDK EVO

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the FAAC SDK EVO and is the answer not in the manual?

FAAC SDK EVO Specifications

General IconGeneral
BrandFAAC
ModelSDK EVO
CategoryControl Unit
LanguageEnglish

Related product manuals