13
+
-
Led ERR ˜
Led ERR Ý
Er...xx...xx... Er...
8.
E2
I4
I3
I1
I2
8.
E1
OFF
OFF
S1
S2
OFF
OFF
Translation of the original instructions
EN GL IS H
FW VERSIONS
The FW version of the board appears on the display when you switch it
on. SDK EVO allows the FW versions of the SDK EVO, the E1SL board,
the DM board, if the DM KIT is installed, and the installed devices to
be displayed.
- from SDK EVO: /INFO
… SDK EVO
SDK EVO BOOT VER x.x BOOTLOADER (NOT updatable)
SDK EVO APP VER x.x FIRMWARE (updatable)
SDK EVO LAN VER x.x LANGUAGE file (updatable)
… E1SL
E1SL BOOT VER x.x BOOTLOADER (NOT updatable)
E1SL APP VER x.x FIRMWARE (updatable)
…
AUTOMATION AND CONFIGURED INPUTS STATUS
The STATUS of the automation is displayed in real time on the board
display ( Status of the automation) and on the SDK EVO.
- from SDK EVO: /PROGRAMMING/INSTALLATION/DOOR STATUS
The STATUS of the configured inputs can be seen:
- from board Advanced Programming: function
In
- from SDK EVO: /PROGRAMMING/INSTALLATION/INPUTS STATUS
Example Input S2 active:
INPUT STATUS
IN4
O2
FSW
OK
IN1
S1
MR
IN2
S2
E1
IN3
O1
E2
ERRORS AND WARNINGS
To display the codes for the current ERRORS/WARNINGS, then see table Errors,
Alarms/Info codes.
- from board: simultaneously press and hold the + and
-
, the display shows:
Er appears on the display and then all the active error/warning codes (e.g.
Er 07 18 ...)
- from SDK EVO: …
…ERRORS
…WARNINGS
i
- The ERRORS stop the automation from operating and are indicated
by: steady RED ERR LED and status
13 on the display.
- The WARNINGS refer to malfunctions that should be investigated, or
operating modes and phases in progress. The ALARMS are indicated
by: flashing RED ERR LED. The INFO notifications do not activate LEDs.
9 Status of the automation
00
CLOSED
01
OPENING
02
OPEN
03
in PAUSE
04
in NIGHT-TIME PAUSE
05
CLOSING
06
OPEN or STOPPED or CLOSED in EMERGENCY (depending on programming)
07
in MANUAL mode
08
in NIGHT-TIME mode
10
System TEST in progress
11
STOPPED
12
Safety TEST in progress
13
Door ERROR (Press + and
-
simultaneously to display the ERROR)
L0
(flashing) SETUP in progress - startup phase
L1
(flashing) SETUP in progress - closing phase
L2
(flashing) SETUP in progress - opening phase
. in SLEEP mode (point flashing)
C
C
Programming is in progress via Simply Connect and programming via the
board is inhibited
Status of configured inputs - shown on the display:
segment lit = input active
(OFF = segment always off)
Manual Release Safeties TEST
Displaying errors/warnings on the display:
See Errors, Alarms/Info codes
(ERRORS)
(WARNINGS)