6.4 Selecting Options
6-23
Chap. 6 SELECTING PERIPHERAL EQUIPMENT
[ 4 ] Extension cable for remote operation
The extension cable connects the inverter with the remote keypad to enable remote operation of the
inverter. The cable is a straight-wired type with RJ-45 jacks and its length is selectable from 16.4, 9.8 and
3.3 ft (5, 3 and 1 m).
Type Length [ft (m)]
CB-5S 16.4 (5)
CB-3S 9.8 (3)
CB-1S 3.3 (1)
[ 5 ] Copy adapter "CPAD-C1A"
The copy adapter can be easily connected to an inverter, and is used to copy data to multiple inverters.
[ 6 ] Inverter support loader software
FRENIC Loader is support software which enables the inverter to be operated via the RS-485
communications facility. The main functions include the following:
- Easy editing of function code data
- Monitoring the operation statuses of the inverter such as I/O monitor and multi-monitor
- Operation of inverters on a PC screen (Windows-based only)
Refer to Chapter 5 "RUNNING THOUGH RS-485 COMMUNICATION (OPTION)" for details.