Chapter 2 Troubleshooting
2.3 Error Code FIP
2-75
FIP2.2 Regi. Sensor [HVPS] (PL18.2.5)
Step Check and Action Yes No
Parts considered to be the cause
ACTUATOR REGI (PL15.2.20)
Regi. Sensor [HVPS] (PL18.2.5)
HARNESS ASSY HV (PL18.3.13)
PWBA MCU (PL18.2.2)
1
Check for foreign substances in the Regi. Sensor [HVPS]
Detector
Are there any foreign substances in the Regi. Sensor
[HVPS] Detector?
Remove the
foreign sub-
stances
Go to Step 2.
2
Check the shape of the ACTUATOR REGI
Is the ACTUATOR REGI damaged?
Replace the
ACTUATOR
REGI
Go to Step 3.
3
Check connector connection
Check the connection between the HVPS and the PWBA
MCU.
Is the HARNESS ASSY HV(P/J261-P/J26) connected
securely?
Go to Step 4.
Securely connect
the HARNESS
ASSY HV
(P/J261-P/J26)
4
Check after replacing the HARNESS ASSY HV
Replace the HARNESS ASSY HV.
Does an error occur?
Go to Step 5. End of work.
5
Check after replacing the HVPS
Replace the HVPS. (REP 18.3)
Does an error occur?
Replace the
PWBA MCU.
(REP 18.2)
End of work.