Chapter 2 Troubleshooting
2.3 Error Code FIP
2-66
FIP1.20 077-300 IOT Cover Front Open
Step Check and Action Yes No
Parts considered to be the cause
KIT COVER ASSY FRONT (PL19.1.7)
Front Interlock Switch [KIT LVPS] (PL18.1.99)
HARNESS ASSY LV (PL18.3.5)
PWB LVPS (PL18.1.5)
PWBA MCU (PL18.2.2)
1
Check the shape of the protruding portion of the KIT
COVER ASSY FRONT
Is the protruding portion of the KIT COVER ASSY FRONT
damaged?
Replace the
KIT COVER
ASSY FRONT
(REP 19.1)
Go to Step 2.
2
Check the operation of the Front Interlock Switch
Execute the Diag Digital Output [041-300] to check the
operation of the Front Interlock Switch.
Is it working properly?
Replace the
PWBA MCU.
(REP 18.2)
Go to Step 3.
3
Check connector connection
Check the connection between the PWB LVPS and the
PWBA MCU.
Is the HARNESS ASSY LV (P/J220-P/J22) connected
securely?
Go to Step 4.
Securely con-
nect the HAR-
NESS ASSY
LV
(P/J220-P/J22)
4
Check after replacing the HARNESS ASSY LV
Replace the HARNESS ASSY LV.
Does an error occur?
Go to Step 5. End of work.
5
Check after replacing the Front Interlock Switch [KIT LVPS]
Replace the Front Interlock Switch [KIT LVPS]. (REP 18.4)
Does an error occur?
Replace the
PWBA MCU.
(REP 18.2)
End of work.