Cauon: The system zeroizaon process can take up to 2 hours to complete. Do not power down the
system during this 2-hour me frame and unl communicaon can be reestablished with the blade aer
the zeroizaon process.
Command:
> request zeroize-system
Output:
The system will be reset to the factory status and cannot be recovered. It will
take a couple of hours to complete. Really want to do this? [no,yes]
Step 3
Enter yes to start zeroizaon of system.
Output:
status Successful
status-message Zeroization of system has started.
Step Result:
The blade is reset to the factory default soware status. The blade reboots aer 3…6 minutes.
Note: sysZeroizaonCompleted alarm is raised before the system is going down for reboot.
Step 4
Aer the system zeroizaon process is completed and the system reboots, reestablish communicaon with the
blade.
✓ This task is complete.
6.6.8
Congure AINS
User can specify the target port for conguring AINS.
Step 1
Retrieve systemwide provisionable meout.
Command:
> show system sys-vstimer
Step 2
Provision system valid signal mer (VSTIMER).
Note: Supported values for VSTIMER are 00-01 to 48-00.
Command Example:
% set system sys-vstimer 08-00
System Administration
System Feature Administration
221
Release 19.1.1 · Issue 1.1, May 2021
Fujitsu and Fujitsu Customer Use Only