Provision Main Blade Ports and Fan Units
Step 1
Provision the Fan unit slots.
Note: If autoprovisioning is enabled, the Fan unit slots are automacally provisioned.
Commands:
% set eqpt shelf 1 slot FAN1 cardType AC00-F011 admin-status up
% set eqpt shelf 1 slot FAN2 cardType AC00-F011 admin-status up
Step 2
Provision the E1 port on the L100 Main blade.
Note: If autoprovisioning is enabled, the E1 port is automacally provisioned.
Command:
% set eqpt shelf 1 slot 0 cardType BDL1-3R11 subslot 0 port E1 admin-status up
pluggableInterfaceType Edge num-lanes 128
Step 3
Provision the client ports (C1…C9) on the L100 Main blade.
Note: If autoprovisioning is enabled, the C1…C9 ports are automacally provisioned.
Command:
% set eqpt shelf 1 slot 0 cardType BDL1-3R11 subslot 0 port C1 admin-status up
pluggableInterfaceType Client num-lanes 128
Note: Repeat this step for each client port (C1…C9) to be provisioned.
Step 4
Provision the logical port.
Note: If autoprovisioning is enabled, the logical port is automacally provisioned.
Command:
% set eqpt shelf 1 slot 0 subslot 0 port L1 pluggableInterfaceType Logical num-
lanes 128 admin-status up
Step 5
Provision the OSC port.
Note: If autoprovisioning is enabled, the OSC port is automacally provisioned.
Command:
% set eqpt shelf 1 slot 0 subslot 0 port OSC pluggableInterfaceType OSC admin-
status up