Enty Type Severity
Service
Aected
Direcon Locaon Descripon
crical service-
aecng
n/a NEND Power Input Fail: TYPE=<unit type>
Probable Cause Suggested Correcve Acon
■The A power feed on the –48 V DC
power adapter has failed.
■The –48 V DC A power feed has failed at
the source.
1. Check the power connecons on the A power feed on
the –48 V DC power adapter and/or the –48 V DC
power source.
2. Check the input voltage at the A power feed on the –
48 V DC power adapter.
powerProblemB
Enty Type Severity
Service
Aected
Direcon Locaon Descripon
BDL1-3B11, BDL1-3R11 major non–service-
aecng
n/a NEND Power Input Fail: TYPE=<unit type>
Probable Cause Suggested Correcve Acon
■The A power feed on the –48 V DC
power adapter has failed.
■The –48 V DC B power feed has failed at
the source.
1. Check the power connecons on the B power feed on
the –48 V DC power adapter and/or the –48 V DC
power source.
2. Check the input voltage at the B power feed on the –48
V DC power adapter.
BDL1-3B11, BDL1-3R11 crical service-
aecng
n/a NEND Power Input Fail: TYPE=<unit type>
Probable Cause Suggested Correcve Acon
■The A power feed on the –48 V DC
power adapter has failed.
■The –48 V DC B power feed has failed at
the source.
1. Check the power connecons on the B power feed on
the –48 V DC power adapter and/or the –48 V DC
power source.
2. Check the input voltage at the B power feed on the –48
V DC power adapter.
System Maintenance
Trouble Clearing
331
Release 19.1.1 · Issue 1.1, May 2021
Fujitsu and Fujitsu Customer Use Only