Enty Type Severity
Service
Aected
Direcon Locaon Descripon
eth warning non–service-
aecng
n/a NEND Administrave State Down: TYPE=<unit
type>
Probable Cause Suggested Correcve Acon
The administrave state of the ETH enty is
set to DOWN.
Change the administrave state to UP.
Port (Edge) warning non–service-
aecng
n/a NEND Administrave State Down: TYPE=<unit
type>
Probable Cause Suggested Correcve Acon
The administrave state of the edge port is
set to DOWN.
Change the administrave state to UP.
Port (Client) warning non–service-
aecng
n/a NEND Administrave State Down: TYPE=<unit
type>
Probable Cause Suggested Correcve Acon
The administrave state of the client port is
set to DOWN.
Change the administrave state to UP.
Port (OSC) warning non–service-
aecng
n/a NEND Administrave State Down: TYPE=<unit
type>
Probable Cause Suggested Correcve Acon
The administrave state of the OSC port is
set to DOWN.
Change the administrave state to UP.
backwardDefectIndication
Enty Type Severity
Service
Aected
Direcon Locaon Descripon
oms warning non–service-
aecng
receive FEND Backward Defect Indicaon
Probable Cause Suggested Correcve Acon
An OMS or OTS layer opcal signal failure,
for example, a WDM LOS, has occurred in
the downstream direcon.
Clear the downstream WDM receive signal failure.
Cauon: The OSC must be acve for trac to be restored.
A failure of the OSC may keep trac from recovering on a
span.
System Maintenance
Trouble Clearing
297
Release 19.1.1 · Issue 1.1, May 2021
Fujitsu and Fujitsu Customer Use Only