postBlockSpanAdjustmentInProgress
Enty Type Severity
Service
Aected
Direcon Locaon Descripon
oms warning non–service-
aecng
n/a NEND Post Block Span Adjustment in Progress:
TYPE = <unit type>
Probable Cause Suggested Correcve Acon
Post block span adjustment is in progress. No acon is required. This condion automacally clears
when the post block span adjustment completes.
powerOutOfSpecicationHigh
Enty Type Severity
Service
Aected
Direcon Locaon Descripon
Subport (Edge) crical service-
aecng
transmit NEND Power Out of Specicaon–High: TYPE =
<unit type>
Probable Cause Suggested Correcve Acon
The opcal power on the indicated transmit
edge subport is too high.
Check the opcal transmit power at the indicated subport.
Subport (Edge) crical service-
aecng
receive NEND Power Out of Specicaon–High: TYPE =
<unit type>
Probable Cause Suggested Correcve Acon
The opcal power on the indicated receive
edge subport is too high.
Check the opcal receive power at the indicated subport.
Subport (Client) crical service-
aecng
transmit NEND Power Out of Specicaon–High: TYPE =
<unit type>
Probable Cause Suggested Correcve Acon
The opcal power on the indicated transmit
client subport is too high.
Check the opcal receive power at the indicated subport.
Port (Edge) crical service-
aecng
transmit NEND Power Out of Specicaon–High: TYPE =
<unit type>
Probable Cause Suggested Correcve Acon
The opcal power on the indicated transmit
edge port is too high.
Check the opcal transmit power at the indicated port.
System Maintenance
Trouble Clearing
325
Release 19.1.1 · Issue 1.1, May 2021