7.11
Adding Degree to ROADM Node
In this secon:
7.11.1 Provision L100 Tributary Blade and Ports
7.11.2 Provision L100 Tributary Blade OTS/OMS/OCH Interfaces
7.11.3 Provision Add/Drop Port Connecons
7.11.4 Provision Cross-Connects
Perform inial setup for the tributary L100 Blade to be added as described in Set Up Tributary Blade without
Auto Shelf ID Assignment Enabled.
Note: The default name must be changed from fujitsu for the system to turn up as well as for the tributary
shelves to be recognized.
7.11.1
Provision L100 Tributary Blade and Ports
Note: The default name must be changed from fujitsu for the system to turn up as well as for the tributary
shelves to be recognized.
Step 1
Provision the L100 tributary blade equipment.
Note: If autoprovisioning is enabled, the L100 tributary blade equipment is automacally provisioned.
Command:
% set eqpt shelf 2 type BDL1-3R11 shelf-mode NORMAL shelf-role TRIB admin-status up
Step 2
Provision the Fan unit slots.
Note: If autoprovisioning is enabled, the Fan unit slots are automacally provisioned.
Commands:
% set eqpt shelf 2 slot FAN1 cardType AC00-F011 admin-status up
% set eqpt shelf 2 slot FAN2 cardType AC00-F011 admin-status up
Step 3
Provision the E1 port on the L100 tributary blade.
Note: If autoprovisioning is enabled, the E1 port is automacally provisioned.
Command:
% set eqpt shelf 2 slot 0 cardType BDL1-3R11 subslot 0 port E1 admin-status up
pluggableInterfaceType Edge num-lanes 128
ROADM Turn-Up and Operations
Adding Degree to ROADM Node
266