bitErrorRateSignalDegrade
Enty Type Severity
Service
Aected
Direcon Locaon Descripon
OC3 OSC (BDL1-3R11) major non–service-
aecng
receive NEND The bit error rate signal degrade count has
exceeded the threshold value.
Probable Cause Suggested Correcve Acon
The OSC receive power has fallen below
or exceeded the specied limit.
A connector in the OSC opcal link is
dirty.
The opposite-end opcal transmier is
creang bit errors. Points of large
opcal reecon exist along the OSC
link.
A hardware problem in the blade could
be causing line BER problems.
The BERSD-L threshold seng may not
be appropriate for the applicaon in
use.
1. Verify the local receive and upstream transmit level.
2. Clean the opcal connectors.
3. Verify good opcal connecons to the local and far-end
blades and at the Lightwave Distribuon Frame (LDF)
panels along the link.
4. Replace the far-end blade.
5. Retrieve the facility and check the BERSD-L threshold
seng in accordance with local pracces.
bitErrorRateSignalFail
Enty Type Severity
Service
Aected
Direcon Locaon Descripon
OC3 OSC (BDL1-3R11) major non–service-
aecng
receive NEND The bit error rate signal failure count has
exceed the threshold value.
Probable Cause Suggested Correcve Acon
The OSC receive power has fallen below
or exceeded the specied limit.
A connector in the OSC opcal link is
dirty.
The opposite-end opcal transmier is
creang bit errors. Points of large
opcal reecon exist along the OSC
link.
A hardware problem in the blade could
be causing line BER problems.
The BERSF-L threshold seng may not
be appropriate for the applicaon in
use.
1. Verify the local receive and upstream transmit level.
2. Clean the opcal connectors.
3. Verify good opcal connecons to the local and far-end
blades and at the LDF panels along the link.
4. Replace the far-end blade.
5. Retrieve the facility and check the BERSF-L threshold
seng in accordance with local pracces.
System Maintenance
Trouble Clearing
298
Release 19.1.1 · Issue 1.1, May 2021
Fujitsu and Fujitsu Customer Use Only