bitErrorRateSignalDegrade
Enty Type Severity
Service
Aected
Direcon Locaon Descripon
OC3 OSC (BDL1-3R11) major non–service-
aecng
receive NEND The bit error rate signal degrade count has
exceeded the threshold value.
Probable Cause Suggested Correcve Acon
■ The OSC receive power has fallen below
or exceeded the specied limit.
■ A connector in the OSC opcal link is
dirty.
■ The opposite-end opcal transmier is
creang bit errors. Points of large
opcal reecon exist along the OSC
link.
■ A hardware problem in the blade could
be causing line BER problems.
■ The BERSD-L threshold seng may not
be appropriate for the applicaon in
use.
1. Verify the local receive and upstream transmit level.
2. Clean the opcal connectors.
3. Verify good opcal connecons to the local and far-end
blades and at the Lightwave Distribuon Frame (LDF)
panels along the link.
4. Replace the far-end blade.
5. Retrieve the facility and check the BERSD-L threshold
seng in accordance with local pracces.
bitErrorRateSignalFail
Enty Type Severity
Service
Aected
Direcon Locaon Descripon
OC3 OSC (BDL1-3R11) major non–service-
aecng
receive NEND The bit error rate signal failure count has
exceed the threshold value.
Probable Cause Suggested Correcve Acon
■ The OSC receive power has fallen below
or exceeded the specied limit.
■ A connector in the OSC opcal link is
dirty.
■ The opposite-end opcal transmier is
creang bit errors. Points of large
opcal reecon exist along the OSC
link.
■ A hardware problem in the blade could
be causing line BER problems.
■ The BERSF-L threshold seng may not
be appropriate for the applicaon in
use.
1. Verify the local receive and upstream transmit level.
2. Clean the opcal connectors.
3. Verify good opcal connecons to the local and far-end
blades and at the LDF panels along the link.
4. Replace the far-end blade.
5. Retrieve the facility and check the BERSF-L threshold
seng in accordance with local pracces.
System Maintenance
Trouble Clearing
298
Release 19.1.1 · Issue 1.1, May 2021
Fujitsu and Fujitsu Customer Use Only