Enty Type Severity
Service
Aected
Direcon Locaon Descripon
Port (Client) crical service-
aecng
receive NEND Power Out of Specicaon–Low: TYPE =
<unit type>
Probable Cause Suggested Correcve Acon
The opcal power on the indicated transmit
edge subport is too low.
Check the opcal transmit power at the indicated port.
Port (OSC) major non–service-
aecng
receive NEND Power Out of Specicaon–Low: TYPE =
<unit type>
Probable Cause Suggested Correcve Acon
The opcal power on the indicated transmit
edge port is too low.
Check the opcal transmit power at the indicated port.
1GEX minor non–service-
aecng
transmit NEND Power Out of Specicaon–Low: TYPE =
<unit type>
Probable Cause Suggested Correcve Acon
The opcal power on the indicated transmit
1GEX interface is too low.
None
1GEX minor non–service-
aecng
receive NEND Power Out of Specicaon–Low: TYPE =
<unit type>
Probable Cause Suggested Correcve Acon
The opcal power on the indicated transmit
1GEX interface is too low.
Check the opcal transmit power at the indicated interface.
1GEX crical service-
aecng
transmit NEND Power Out of Specicaon–Low: TYPE =
<unit type>
Probable Cause Suggested Correcve Acon
The opcal power on the indicated transmit
1GEX interface is too low.
Check the opcal transmit power at the indicated interface.
1GEX crical service-
aecng
receive NEND Power Out of Specicaon–Low: TYPE =
<unit type>
Probable Cause Suggested Correcve Acon
The opcal power on the indicated receive
1GEX interface is too low.
Check the opcal receive power at the indicated interface.